Recovery Equipment With Low Pressure Switch R32 Easyrec-1 Wigam
WI13001019 ✅ Automatic evacuation device that makes it easy to change the type of refrigerant.
✅ Equipped with a low-pressure switch that switches off the unit once refrigerant recovery has finished, avoiding compressor breakdown problems caused by running without refrigerant.
✅ Visual signal (green LED) for end of recovery.
✅ High-pressure safety device.
✅ Equipped with two shut-off valves that prevent refrigerant leakage.
✅ “Pulse Free” pressure gauges with adjustment screw.
✅ “High Resistance” ceramic cylinder with carbon fibre gasket.
✅ Sight glass and filter included.
✅ Large graphic with quick operating instructions.
✅ Can be used with R32 and R1234ze, exclusively by authorised personnel with specific training in the use of these gases.
✅ Technical specifications.
✅ Refrigerants CFC, HCFC, HFC and HFO (including R32 and R1234ze).
✅ Power supply: 220 - 240V AC 50 - 60 Hz.
✅ Power: 550W.
✅ Maximum absorbed current: 4A.
✅ Compressor: Piston, oil-free.
✅ Automatic safety lock: 38.5 bar/3850 kPa (558 psi).
✅ Working temperature: 0 - 40 ºC.
✅ Recovery capacity.
✅ Vapour R12-R134a: 14 kg/h R22-R407C: 15 kg/h R404A-R410A-R507-R32: 16 kg/h.
✅ Liquid (recovery) R12-R134a: 96 kg/h R22-R407C: 108 kg/h 404A-R410A-R507-R32: 132 kg/h.
✅ Push-pull R12-R134a: 276 kg/h R22-R407C: 336 kg/h R404A-R410A-R507-R32. 378 kg/h.